Thermocouple Calibrator
PSIP 702
Through/Cut Check
Explanation | Accuracy | Resolution | Output Range | Range | output |
---|---|---|---|---|---|
the Max Output Current ±5mA | ±0.05% Setting Value ±30µV | 0.01mV | -10.00~110,00mV | 100mV | Voltage |
the Max Output Current ±5mA | ±0.05% Setting Value ±0.3mV | 0.1mV | -100.00~1100,00mV | 1000mV | Voltage |
Adopt the ITS-90 Temperature Standard | ±0.05% Setting Value ±3C(≤100C) | 1C | -40~1760C | R | Thermocuouple |
Adopt the ITS-90 Temperature Standard | ±0.05% Setting Value ±2C(>100C) | 1C | -20~1760C | S | Thermocuouple |
Adopt the ITS-90 Temperature Standard | ±0.05% Setting Value ±3C(400~600C) | 1C | -400~1800C | B | Thermocuouple |
Adopt the ITS-90 Temperature Standard | ±0.05% Setting Value ±3C(>600C) | 1C | -400~1800C | B | Thermocuouple |
Adopt the ITS-90 Temperature Standard | (±0.05% Setting Value) (±2C(≤-100C)) (±0.05& Setting Value) (±1c(>-100c) | 0.1C | -200.0~1000.0C | E | Thermocuouple |
Adopt the ITS-90 Temperature Standard | (±0.05% Setting Value) (±2C(≤-100C)) (±0.05% Setting Value) ±1c(>-100c) | 0.1C | -200.0~1370.0C | K | Thermocuouple |
Adopt the ITS-90 Temperature Standard | (±0.05% Setting Value) (±2C(≤-100C)) (±0.05% Setting Value) ±1c(>-100c) | 0.1C | -200.0~1200.0C | J | Thermocuouple |
Adopt the ITS-90 Temperature Standard | (±0.05% Setting Value) (±2C(≤-100C)) (±0.05% Setting Value) ±1c(>-100c) | 0.1C | -200.0~400.0C | T | Thermocuouple |
Adopt the ITS-90 Temperature Standard | (±0.05% Setting Value) (±2C(≤-100C)) (±0.05% Setting Value) ±1c(>-100c) | 0.1C | -200.0~1300.0C | N | Thermocuouple |
Through/Cut Check
Explanation | Accuracy | Resolution | Intput Range | Range | Intput |
---|---|---|---|---|---|
Input Resistance 1MΩ | ±0.05% Measuring Value ±30µV | 10µV | -10.00~110.00mV | 100mV | Voltage |
Input Tesistance 1MΩ adopt the ITS-90 Tempreture Standard | ±0.05% Measuring Value ±3C | 1C | -40~1760C | R | Thermocouple |
Input Tesistance 1MΩ adopt the ITS-90 Tempreture Standard | ±0.05% Measuring Value ±2C(>100C>) | 1C | -20~1760C | S | Thermocouple |
Input Tesistance 1MΩ adopt the ITS-90 Tempreture Standard | ±0.05% Measuring Value ±3C(400~600C) | 1C | 400~1800C | B | Thermocouple |
Input Tesistance 1MΩ adopt the ITS-90 Tempreture Standard | ±0.05% Setting Value ±2C(>600C) | 1C | 400~1800C | B | Thermocouple |
Input Tesistance 1MΩ adopt the ITS-90 Tempreture Standard | ±0.05% Measuring Value ±2C(≤-100C) ±0.05% Setting Value ±1C(>-100C) | 0.1C | -200.0~1370.0C | E | Thermocouple |
Input Tesistance 1MΩ adopt the ITS-90 Tempreture Standard | ±0.05% Measuring Value ±2C(≤-100C) ±0.05% Setting Value ±1C(>-100C) | 0.1C | -200.0~1200.0C | K | Thermocouple |
Input Tesistance 1MΩ adopt the ITS-90 Tempreture Standard | ±0.05% Measuring Value ±2C(≤-100C) ±0.05% Setting Value ±1C(>-100C) | 0.1C | -200.0~1200.0C | J | Thermocouple |
Input Tesistance 1MΩ adopt the ITS-90 Tempreture Standard | ±0.05% Measuring Value ±2C(≤-100C) ±0.05% Setting Value ±1C(>-100C) | 0.1C | -200.0~400.0C | T | Thermocouple |
Input Tesistance 1MΩ adopt the ITS-90 Tempreture Standard | ±0.05% Measuring Value ±2C(≤-100C) ±0.05% Setting Value ±1C(>-100C) | 0.1C | -200.0~1300.0C | N | Thermocouple |